PRODUCTS
POWER SUPPLIES with TOROIDAL TRANSFORMER |
MODEL | FT146 | FT1413 | FT1426 | |
Input | Vac Hz | 230 50 | 230 50 | 230 50 |
Output | Vdc | 13.8 internal adjustment | 13.8 internal adjustment | 13.8 internal adjustment |
Max Load | A | 5 | 13 | 26 |
Stability | . | 1% from unloaded to full load | 1% from unloaded to full load | 1% from unloaded to full load |
Ripple | . | 5 mV pp | 5 mV pp | 5 mV pp |
Dimensions (LxWxH) | mm | 180 x 170 x 44 | 180 x 170 x 64 | 230 x 170 x 135 |
Weight | Kg | 2 | 3 | 4.6 |
. | . | Protected against permanent short circuit, fold back current limiting | ||
. | . | “SUITABLE DESIGN FOR RADIO-COMMUNICATION” |
POWER SUPPLIES |
MODEL | 142 | 143 | 152 | HP145 | HP147 | |
Input | Vac Hz | 230 50 | 230 50 | 230 50 | 230 50 | 230 50 |
Output | Vdc | 13.8 | 13.8 | 3 ÷ 15 adjustable | 13.8 | 13.8 |
Max Load | A | 2.5 | 3.5 | 2.5 | 5 | 7 |
Dimensions (LxWxH) | mm | 150 x 160 x 90 | 150 x 160 x 90 | 150 x 160 x 90 | 220 x 135 x 90 | 220 x 135 x 90 |
Weight | Kg | 1.25 | 1.25 | 1.25 | 2.45 | 2.8 |
. | . | “SUITABLE DESIGN FOR RADIO-COMMUNICATION” |
MODEL | HP156S | HP12 | HP12S | |
Input | Vac Hz | 230 50 | 230 50 | 230 50 |
Output | Vdc | 4 ÷ 16 | 13.8 internal adjustment | 4 ÷ 17 |
Max Load | A | 7 | 12 | 12 |
Stability | . | 1% from unloaded to full load | 1% from unloaded to full load | 1% from unloaded to full load |
Ripple | . | 5 mV pp | 5 mV pp | 5 mV pp |
Dimensions (LxWxH) | mm | 220 x 135 x 90 | 260 x135 x 105 | 260 x135 x 105 |
Weight | Kg | 3.15 | 4.1 | 4.1 |
. | . | Lighted Volt and Ampere meter | .. | Lighted Volt and Ampere meter |
. | . | Protected against permanent short circuit, fold back current limiting | ||
. | . | “SUITABLE DESIGN FOR RADIO-COMMUNICATION” |
MODEL | 1240-1 | 1240S | 2420 (24V) | |
Input | Vac Hz | 230 50 | 230 50 | 230 50 |
Output | Vdc | 13.8 internal adjustment | 5 ÷ 17 | 24 internal adjustment |
Max Load | A | 40 | 40 | 20 |
Stability | . | 1% from unloaded to full load | 1% from unloaded to full load | 1% from unloaded to full load |
Ripple | . | 5 mV pp | 5 mV pp | 5 mV pp |
Dimensions (LxWxH) | mm | 190 x 280 x 140 | 190 x 280 x 140 | 190 x 280 x 140 |
Weight | Kg | 9.5 | 9.5 | 9.5 |
. | . | . | Lighted Volt and Ampere meter | |
. | . | Protected against permanent short circuit, fold back current limiting | ||
. | . | “SUITABLE DESIGN FOR RADIO-COMMUNICATION” |
MODEL | 1250-1 | 1250S | |
Input | Vac Hz | 230 50 | 230 50 |
Output | Vdc | 13.8 internal adjustment | 5 ÷ 18 |
Max Load | A | 50 | 50 |
Stability | . | 1% from unloaded to full load | 1% from unloaded to full load |
Ripple | . | 5 mV pp | 5 mV pp |
Dimensions (LxWxH) | mm | 345 x 315 x 165 | 345 x 315 x 165 |
Weight | Kg | 17.5 | 17.5 |
. | . | . | Lighted Volt and Ampere meter |
. | . | Protected against permanent short circuit, fold back current limiting | |
. | . | “SUITABLE DESIGN FOR RADIO-COMMUNICATION” |
MODEL | 3006 Professional Line | 3020 Professional Line | |
Input | Vac Hz | 230 50 | 230 50 |
Output | Vdc | 0 ÷ 30 | 0 ÷ 30 |
Max Load | A | 0 ÷ 6 continuous service | 0 ÷ 20 continuous service |
Stability | . | better then 0.01% | better then 0.01% |
Ripple | . | 5 mV pp | 5 mV pp |
Dimensions (LxWxH) | mm | 345 x 285 x 165 | 345 x 315 x 165 |
Weight | Kg | 10 | 18 |
. | . | Lighted Volt and Ampere meter | |
. | . | Protected against permanent short circuit, fold back current limiting | |
. | . | “SUITABLE DESIGN FOR RADIO-COMMUNICATION” |
ARCHIVE